Abstract
The aim of this study was to demonstrate the feasibility of using diffusion-weighted (DW) magnetic resonance (MR) imaging under free breathing for the detection of a urinary bladder carcinoma. In 15 patients with 17 urinary bladder carcinomas, DW images were obtained in the axial plane under free breathing scanning with a multisection spin-echo type single-shot echo planar sequence with a body coil. DW images were evaluated based on cystoscopic findings. Moreover, the apparent diffusion coefficient (ADC) value was measured in a circular region of interest (ROI) within the carcinoma, urine, normal bladder wall, prostate and seminal vesicle. In the results, on the DW images, all 17 carcinomas were clearly shown as high signal intensity relative to the surrounding structure. The ADC value (×10−3 mm2/s) in the carcinoma was 1.18±0.19, which was significantly lower compared with that of urine (3.28±0.20), the normal bladder wall (2.27±0.24), prostate (transition zone: 1.57±0.09, peripheral zone:1.85±0.22) and seminal vesicle (2.01±0.22). In conclusion, DW images under free breathing enabled the clear detection of the urinary bladder carcinoma, whose ADC values were lower compared with those of the surrounding structure. The DW images may be useful in evaluating tumors invading to the surrounding structures.
Similar content being viewed by others
References
Kim T, Murakami T, Takahashi S, Hori M, Tsuda K, Nakamura H (1999) Diffusion-weighted single-shot echoplanar MR imaging for liver disease. AJR Am J Roentgenol 173:393–398
Taouli B, Vilgrain V, Dumont E, Darie JL, Fan B, Menu Y (2003) Evaluation of liver diffusion isotrophy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: prospective study in 66 patients. Radiology 226:71–78
Namimoto T, Yamashita Y, Sumi S, Tang Y, Takahashi M (1997) Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging. Radiology 204:739–744
Cova M, Squillaci E, Stacul F et al (2004) Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results. Br J Radiol 77:851–857
Thoeny HC, Keyzer FD, Oyen RH, Peeters RR (2005) Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. Radiology 235:911–917
Issa B (2002) In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging. J Magn Reson Imaging 16:196–200
Shimofusa R, Fujimoto H, Akamata H et al (2004) Diffusion-weighted imaging of prostate cancer. J Compt Assist Tomogr 29:149–153
Sato C, Naganawa S, Nakamura T et al (2005) Differentiation of non-cancerous tissue and cancer lesions by apparent diffusion coefficient values in transition and peripheral zones of the prostate. J Magn Reson Imaging 21:258–262
Nasu K, Kuroki Y, Kuroki S, Murakami K, Nawano S, Moriyama N (2004) Diffusion-weighted single shot planar imaging of colorectal cancer using a sensitivity-encoding technique. Jpn J Clin Oncol 34:620–626
Takahara T, Imai Y, Yamashita T, Yasuda S, Nasu S, Cauteren MV (2004) Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med 22:275–282
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Matsuki, M., Inada, Y., Tatsugami, F. et al. Diffusion-weighted MR imaging for urinary bladder carcinoma: initial results. Eur Radiol 17, 201–204 (2007). https://doi.org/10.1007/s00330-006-0281-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-006-0281-7